神经病学和神经科学杂志

  • 国际标准期刊号: 2171-6625
  • 期刊 h 指数: 17
  • 期刊引用分数: 4.43
  • 期刊影响因子: 3.38
索引于
  • 打开 J 门
  • Genamics 期刊搜索
  • 全球影响因子 (GIF)
  • 中国知网(CNKI)
  • 研究期刊索引目录 (DRJI)
  • OCLC-WorldCat
  • 普罗奎斯特传票
  • 科学期刊影响因子 (SJIF)
  • 欧洲酒吧
  • 谷歌学术
  • 秘密搜索引擎实验室
分享此页面

抽象的

The Effect of Hyperoxia in Traumatic Brain Injury Patients in the Intensive Care Unit of a Tertiary Care Center

Sarah Alromaih,  Hind Alshabanat,  Nosaiba Alshanqiti,  Almaha Aldhuwaihy,  Sarah Abdullah Almohanna, Muna Alqasem,  Fatmah Othman and Raymond M. Khan

Background: Traumatic brain injury (TBI) is a leading cause of morbidity and mortality globally. Currently, the association between hyperoxia and outcomes in patients with TBI remains debatable. We assessed the effect of hyperoxia on the neurological outcomes and survival of critically ill patients with moderate-severe TBI.

Methods: This was a retrospective cohort study of all adults with moderatesevere TBI admitted to the ICU between 1st January 2016 and 31st December 2019 who required invasive mechanical ventilation. We noted ABGs performed with the first 3 hours of intubation, then 6-12 hours and 24-48 hours. The patients were divided into two categories: normoxia (PaO2 60-99 mmHg) and hyeroxia (PaO2 >100 mmHg). Multivariable logistic regression was performed to assess predictors of hospital mortality and good neurologic outcome (Glasgow outcome score [GOS] ≥ 4). In a second analysis the patients were divided into survivors and non-survivors.

Results: The study included 308 patients: 23.4% (n=72) in normoxia group and 76.6% (n=236) in hyeroxia group. Hyperoxia was not associated with increased hospital (43% vs. 18%, p=0.20) mortality. Further, the hospital discharge GCS (10 ± 5 vs. 11 ± 4, p=0.10) and GOS (3 ± 1 vs. 3 ± 1, p=0.35) were similar. In multivariable logistic regression analysis, hyperoxia was not associated with increased mortality (adjusted odds ratio [aOR] 0.99, 95% CI 0.99-1.00, p=0.11). PaO2 within different ranges was also not associated with mortality: 100-200 mmHg: aOR 0.60, 95% CI 0.29-1.52; 201-300 mmHg: aOR 0.66, 95% CI 0.29-1.52; 301-400 mmHg: aOR 0.80, 95% CI 0.31-2.09; and >400 mmHg: aOR 0.39, 95% CI 0.14-1.08; reference: PaO2 60-99 mmHg. The Kaplan-Meier survival curve for normoxia verses hyperoxia showed no significant difference for all-cause mortality. In the survivors verse nonsurvivors analysis, the PaO2 were (median, IQT) 199 mmHg (111-329) and 165 mmHg (84-252), respectively.

Conclusion: Hyperoxia (PaO2 >100 mmHg) was not associated with increased mortality or poor neurological outcomes (determined by GOS) in moderatesevere TBI patients.